Brookfield DV2T Extra Viscometer Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Měřící nástroje Brookfield DV2T Extra Viscometer. Brookfield DV2T Extra Viscometer User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 95
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
SPECIALISTS IN THE
MEASUREMENT AND
CONTROL OF VISCOSITY
TEL 508-946-6200
F
AX 508-946-6262
or 800-628-8139 (USA excluding MA)
I
NTERNET
http://www .brookfieldengineering.com
BROOKFIELD ENGINEERING LABORATORIES, INC.
11 Commerce Boulevard, Middleboro, MA 02346 USA
with offices in
:
BostonChicagoLondonStuttgartGuangzhou
BROOKFIELD DV2T
Viscometer
Operating Instructions
Manual No. M13-167-B0614
Zobrazit stránku 0
1 2 3 4 5 6 ... 94 95

Shrnutí obsahu

Strany 1 - BROOKFIELD DV2T

SPECIALISTS IN THEMEASUREMENT ANDCONTROL OF VISCOSITYTEL 508-946-6200FAX 508-946-6262or 800-628-8139 (USA excluding MA)INTERNET http:/

Strany 2

Brookeld Engineering Labs., Inc. Page 10 Manual No. M13-167-B06147) Make sure that theAC power switch at the rear of the DV2T is

Strany 3 - Table of Contents

Brookeld Engineering Labs., Inc. Page 11 Manual No. M13-167-B0614 I.5 Safety Symbols and PrecautionsSafety SymbolsThefollowingexplainssafe

Strany 4 - Tearoutpage

Brookeld Engineering Labs., Inc. Page 12 Manual No. M13-167-B0614Status Bar: TheStatusBarprovidesinformationrelatingtothedateandtime

Strany 5 - I. INTRODUCTION

Brookeld Engineering Labs., Inc. Page 13 Manual No. M13-167-B0614II. GETTING STARTED II.1 Power UpThe DV2T will go through a Power Up

Strany 6 - DV2T DV2T Extra

Brookeld Engineering Labs., Inc. Page 14 Manual No. M13-167-B0614Figure II-2Theoperatormustensurethattheviscometerislevel(seeSection

Strany 7 - COMPONENT DIAGRAM

Brookeld Engineering Labs., Inc. Page 15 Manual No. M13-167-B0614 II.4 Navigation   TheDV2TViscometerusesatouchscreendisplay.Naviga

Strany 8

Brookeld Engineering Labs., Inc. Page 16 Manual No. M13-167-B0614 II.5 Home Screen TheDV2THomescreencanbeaccessedbyusingtheHomeIco

Strany 9

Brookeld Engineering Labs., Inc. Page 17 Manual No. M13-167-B0614More/Less BarCommand KeysStatus BarTitle BarTest ParametersTest Name

Strany 10

Brookeld Engineering Labs., Inc. Page 18 Manual No. M13-167-B0614Torque: Alivesignalfromtheviscometer.Spindle: Thecurrentlyselectedspin

Strany 11

Brookeld Engineering Labs., Inc. Page 19 Manual No. M13-167-B0614 II.5.3 View Results Testresults(datales)canbesavedtotheinternal

Strany 13 - II. GETTING STARTED

Brookeld Engineering Labs., Inc. Page 20 Manual No. M13-167-B0614 Range Figure II-6TIP: The Rangevalue isthe same a

Strany 14

Brookeld Engineering Labs., Inc. Page 21 Manual No. M13-167-B0614Measurementdatashouldnotbecollectedwhenthe%Torquereadingisoutofra

Strany 15

Brookeld Engineering Labs., Inc. Page 22 Manual No. M13-167-B0614Printerformatisdetailedbelow:Data Label (Small) Data Label (Large)

Strany 16

Brookeld Engineering Labs., Inc. Page 23 Manual No. M13-167-B0614III. MAKING VISCOSITY MEASUREMENTS III.1 Quick StartTheDV2TViscometeruse

Strany 17 - Run: Runthecurrenttest

Brookeld Engineering Labs., Inc. Page 24 Manual No. M13-167-B0614  Manysamplesmustbecontrolledtoaspecictemperatureforviscositymea

Strany 18

Brookeld Engineering Labs., Inc. Page 25 Manual No. M13-167-B0614IfyourinstrumenthastheEZ-Locksystem,thespindlesareattachedasfollow

Strany 19

Brookeld Engineering Labs., Inc. Page 26 Manual No. M13-167-B0614Figure III-3Figure III-4 Single Point:Collectonlyasingledatapointwhe

Strany 20

Brookeld Engineering Labs., Inc. Page 27 Manual No. M13-167-B0614 Multi Point:Collectmultipledatapointsbasedontime.TheDataInterval

Strany 21

Brookeld Engineering Labs., Inc. Page 28 Manual No. M13-167-B0614CollectSinglePointatStepEnd.Duringthetest,thetotaltimerequiredto

Strany 22

Brookeld Engineering Labs., Inc. Page 29 Manual No. M13-167-B0614thenrerunningthetest(seeSectionIII.8).Thismethodcanallowyoutoqui

Strany 23

Table of ContentsI. INTRODUCTION ... 5 I.1 Components ...

Strany 24 - Figure III-1

Brookeld Engineering Labs., Inc. Page 30 Manual No. M13-167-B0614 QC Limits: Selectan acceptablerange for measurement results. The

Strany 25 - Figure III-2

Brookeld Engineering Labs., Inc. Page 31 Manual No. M13-167-B0614Instructions: Recordspecicinstructionstotheoperator.Thisinformation

Strany 26

Brookeld Engineering Labs., Inc. Page 32 Manual No. M13-167-B0614 III.8 Running a TestA viscosity test is started by pressing the Run

Strany 27

Brookeld Engineering Labs., Inc. Page 33 Manual No. M13-167-B0614Shear Rateiscalculatedfromtheselectedspeedbasedontheselectedspindle

Strany 28

Brookeld Engineering Labs., Inc. Page 34 Manual No. M13-167-B0614Figure III-10TheMore/LessBarcanbeusedtoreducethenumberofparameters

Strany 29

Brookeld Engineering Labs., Inc. Page 35 Manual No. M13-167-B0614TheResultsscreenincludesseveralNavigationIconsandCommandKeys.Home: R

Strany 30

Brookeld Engineering Labs., Inc. Page 36 Manual No. M13-167-B0614Post Test Averaging: AverageandStandardDeviationarecalculatedformeasur

Strany 31

Brookeld Engineering Labs., Inc. Page 37 Manual No. M13-167-B0614Materialsthatexhibitthixotropywillshowasteadilydecreasingmeasuredvis

Strany 32

Brookeld Engineering Labs., Inc. Page 38 Manual No. M13-167-B0614Step Averaging:CalculateAverageandStandardDeviationforalldatacollecte

Strany 33

Brookeld Engineering Labs., Inc. Page 39 Manual No. M13-167-B0614IV. SETTINGSTheSettingsmenuprovidesaccesstothemanycontrolsandfeature

Strany 34

 IV.4.3SetTimeandDate ... 52 IV.4.4Bac

Strany 35

Brookeld Engineering Labs., Inc. Page 40 Manual No. M13-167-B0614WhenTemperatureisselectedintheDeviceSetupmenu,theTemperatureOffset

Strany 36

Brookeld Engineering Labs., Inc. Page 41 Manual No. M13-167-B0614AutoZero: AutoZero is an operation performed by the DV2T Viscometera

Strany 37

Brookeld Engineering Labs., Inc. Page 42 Manual No. M13-167-B0614TheOscillationCheckisnotaguaranteeofpropercalibration.Itisonlyan

Strany 38

Brookeld Engineering Labs., Inc. Page 43 Manual No. M13-167-B0614Sound - AdjustthevolumeoftheDV2Tsoundsandselectwhichsounds to silenc

Strany 39 - IV. SETTINGS

Brookeld Engineering Labs., Inc. Page 44 Manual No. M13-167-B0614Change Password: Aspecicusercanchangetheirownpasswordatanytime.T

Strany 40

Brookeld Engineering Labs., Inc. Page 45 Manual No. M13-167-B0614Temperature C CentigradeF Fahrenheit100C=5/9*(212F–32)Stress(Shear)

Strany 41

Brookeld Engineering Labs., Inc. Page 46 Manual No. M13-167-B0614Global Alarm: The GlobalAlarm establishesa singlemeasurement parameter

Strany 42

Brookeld Engineering Labs., Inc. Page 47 Manual No. M13-167-B0614TIP: TheGlobalAlarmsoundcanbeturnedoffintheSoundsmenuof User Sett

Strany 43

Brookeld Engineering Labs., Inc. Page 48 Manual No. M13-167-B0614ASpecialSpindleiscreatedbyselectingtheSpecialSpindlecommandbuttoni

Strany 44

Brookeld Engineering Labs., Inc. Page 49 Manual No. M13-167-B0614TIP: TheselectionofspeedcanberestrictedbyUserLogIn.Usethisrest

Strany 45

Brookeld Engineering Labs., Inc. Page 5 Manual No. M13-167-B0614I. INTRODUCTIONTheBrookeldDV-IIViscometerserieshasbeentheleadingindus

Strany 46

Brookeld Engineering Labs., Inc. Page 50 Manual No. M13-167-B0614TheLogIncheckboxcontrolstheLogInrequirement.WhenLogInischecked,

Strany 47

Brookeld Engineering Labs., Inc. Page 51 Manual No. M13-167-B0614Table IV-1: Factory Default User SettingsAdministrator Power User UserGeneral

Strany 48

Brookeld Engineering Labs., Inc. Page 52 Manual No. M13-167-B0614 IV.4.3 Set Time and DateTheTimeand Dateisdisplayed ontheStatusBar

Strany 49

Brookeld Engineering Labs., Inc. Page 53 Manual No. M13-167-B0614 IV.4.5 Default PathThePathisthelocationwheredataortestsarestored.

Strany 50

Brookeld Engineering Labs., Inc. Page 54 Manual No. M13-167-B0614 IV.4.8 Calibration ReminderTheDV2Tcanbeprogrammedtoprovidetheuserw

Strany 51

Brookeld Engineering Labs., Inc. Page 55 Manual No. M13-167-B0614V. PG FLASH SOFTWAREViscosityTestprogramsfortheDV2Tcanbecreatedona

Strany 52

Brookeld Engineering Labs., Inc. Page 56 Manual No. M13-167-B0614Spindle: The spindle to be used with thisViscosityTest.Allcalculati

Strany 53 - DATA LOSS POSSIBLE!

Brookeld Engineering Labs., Inc. Page 57 Manual No. M13-167-B0614Units SetupFigure V-2Sample Viscosity Test programs can be seen in the

Strany 54

Brookeld Engineering Labs., Inc. Page 58 Manual No. M13-167-B0614Appendix A - Cone/Plate Viscometer Set-UpThis Cone/Plate version of the D

Strany 55 - V. PG FLASH SOFTWARE

Brookeld Engineering Labs., Inc. Page 59 Manual No. M13-167-B0614 A.2 Setup1. Be sure that the Viscometer is securelymountedtotheL

Strany 56

Brookeld Engineering Labs., Inc. Page 6 Manual No. M13-167-B0614All units of measurement are displayed according to either the CGS system or th

Strany 57

Brookeld Engineering Labs., Inc. Page 60 Manual No. M13-167-B0614 A.3 Setting the Gap1. Movethetoggleswitchtotheright;thiswillturn

Strany 58 - ºC. Personal

Brookeld Engineering Labs., Inc. Page 61 Manual No. M13-167-B0614 A.4 Verifying Calibration1. Determinetheappropriatesamplevolume.Refe

Strany 59 - Note: LeftHandThreads

Brookeld Engineering Labs., Inc. Page 62 Manual No. M13-167-B0614Appendix B - Viscosity RangesViscosity Range TablesViscosityrangesshownare

Strany 60 - Figure A-6

Brookeld Engineering Labs., Inc. Page 63 Manual No. M13-167-B0614UL AdapterUL SpindleViscosity (cP)Shear Rate sec-1DV2TLV DV2TRV DV2THA DV2THBY

Strany 61

Brookeld Engineering Labs., Inc. Page 64 Manual No. M13-167-B0614Vane SpindlesSpindle Torque RangeShear Stress Range (Pa)Viscosity Range cP (mP

Strany 62 - Appendix B - Viscosity Ranges

Brookeld Engineering Labs., Inc. Page 65 Manual No. M13-167-B06141) Viscositymeasurementsshouldbeacceptedwithintheequivalent%TorqueR

Strany 63

Brookeld Engineering Labs., Inc. Page 66 Manual No. M13-167-B0614Appendix C - Variables in Viscosity MeasurementsAs with any instrument mea

Strany 64 - Pa=Pascal

Brookeld Engineering Labs., Inc. Page 67 Manual No. M13-167-B0614Viscometer Related VariablesMostuidviscositiesarefoundtobenon-Newtonia

Strany 65

Brookeld Engineering Labs., Inc. Page 68 Manual No. M13-167-B0614Appendix D - Spindle Entry Codes and SMC/SRC ValuesWhenusingastandardBrook

Strany 66

Brookeld Engineering Labs., Inc. Page 69 Manual No. M13-167-B0614SPINDLE ENTRY CODE SMC SRCT-B 92 40 0T-C 93 100 0T-D 94 200 0T-E 95 500 0T

Strany 67

Brookeld Engineering Labs., Inc. Page 7 Manual No. M13-167-B0614COMPONENT DIAGRAMCone/Plate OptionTemperature ProbeSpindle SetCone SpindleWrenc

Strany 68 - Table D-1

Brookeld Engineering Labs., Inc. Page 70 Manual No. M13-167-B0614TableD-2liststhemodelcodesandspringtorqueconstantsforeachViscomete

Strany 69

Brookeld Engineering Labs., Inc. Page 71 Manual No. M13-167-B0614Appendix E - Spindle Entry Codes and Range CoecientsTherangecoefcientisa

Strany 70 - Table D-2

Brookeld Engineering Labs., Inc. Page 72 Manual No. M13-167-B0614Spindle Entry CodeRangeCoefcientLV RV HA HBT-A91 18,750200,000 400,000 1,600

Strany 71 - LV RV HA HB

Brookeld Engineering Labs., Inc. Page 73 Manual No. M13-167-B0614Appendix F - Calibration ProceduresTheaccuracyoftheDV2Tisveriedusingv

Strany 72 - Table E-1

Brookeld Engineering Labs., Inc. Page 74 Manual No. M13-167-B0614BrookeldViscosityStandardFluidGeneralInformation We recommendthat Broo

Strany 73 - +/-)0.1°C

Brookeld Engineering Labs., Inc. Page 75 Manual No. M13-167-B0614Calibration Procedure for a Small Sample Adapter Brookeldrecommendsatwost

Strany 74 - Note: The spindle

Brookeld Engineering Labs., Inc. Page 76 Manual No. M13-167-B0614WhenaULorDINULAdapterisused,thewaterbathisstabilizedattheprope

Strany 75 - Note: The spindle must

Brookeld Engineering Labs., Inc. Page 77 Manual No. M13-167-B0614However,instrumentaccuracyis±2%ofthemaximumviscosityrangeandnot the

Strany 76 - Note: The spindle

Brookeld Engineering Labs., Inc. Page 78 Manual No. M13-167-B0614SmallSampleAdapter,ULAdapter,Thermosel,SpiralAdapter,andDINAdapter,

Strany 77

Brookeld Engineering Labs., Inc. Page 79 Manual No. M13-167-B06142) TheViscosityStandardFluidis101.5cP.Itsaccuracyis:  +/-1%x10

Strany 78

Brookeld Engineering Labs., Inc. Page 8 Manual No. M13-167-B0614 I.2 UtilitiesInputVoltage: UniversalPowerSupply(90-264VAC)InputFrequ

Strany 79

Brookeld Engineering Labs., Inc. Page 80 Manual No. M13-167-B0614Appendix G - The Brookeld GuardlegTheguardlegwasoriginallydesignedtopr

Strany 80

Brookeld Engineering Labs., Inc. Page 81 Manual No. M13-167-B0614MoreSolutionstoStickyProblems.Itisimportanttonotethatformanyvis

Strany 81 - 1 7/163 3/16

Brookeld Engineering Labs., Inc. Page 82 Manual No. M13-167-B0614Appendix H - Speed SelectionBrookeldViscometersofferavarietyofspeedsto

Strany 82 - Appendix H - Speed Selection

Brookeld Engineering Labs., Inc. Page 83 Manual No. M13-167-B0614Appendix I - Laboratory StandsModelGisthestandardlaboratorystandwhichc

Strany 83

Brookeld Engineering Labs., Inc. Page 84 Manual No. M13-167-B0614ModelQisanoptionallaboratorystandwhichcanbeorderedforusewiththe

Strany 84 - Actuation lever for

Brookeld Engineering Labs., Inc. Page 85 Manual No. M13-167-B0614UnpackingCheckcarefullytoseethatallthecomponentsarereceivedwithnoc

Strany 85

Brookeld Engineering Labs., Inc. Page 86 Manual No. M13-167-B0614Appendix J - DVE-50A Probe ClipProbeClipDVE-50AissuppliedwithallmodelD

Strany 86 - Figure J-3

Brookeld Engineering Labs., Inc. Page 87 Manual No. M13-167-B0614Appendix K - Screen Protector TheBrookeldDV2TViscometerisprovidedwitha

Strany 87 - Appendix K - Screen Protector

Brookeld Engineering Labs., Inc. Page 88 Manual No. M13-167-B0614Step3:• CompletelyremoveTab1(seeFigureK-3).• Lightlypressthescreen

Strany 88 - Figure K-5

Brookeld Engineering Labs., Inc. Page 89 Manual No. M13-167-B0614Appendix L - Fault Diagnosis and Troubleshooting Listedaresomeofthemorec

Strany 89 - Inaccurate Readings

Brookeld Engineering Labs., Inc. Page 9 Manual No. M13-167-B0614ElectricalCertications: ConformstoCEStandards:BSEN61326: Electricalequi

Strany 90

Brookeld Engineering Labs., Inc. Page 90 Manual No. M13-167-B0614❏ Viscometer Will Not Return to Zero ✓ Viscometerisnotlevel  • Check

Strany 91

Brookeld Engineering Labs., Inc. Page 91 Manual No. M13-167-B0614Appendix M - Instrument Dimensions

Strany 92

Brookeld Engineering Labs., Inc. Page 92 Manual No. M13-167-B0614Appendix N - Online Help and Additional Resourceswww.brookeldengineering.com*

Strany 93

Brookeld Engineering Labs., Inc. Page 93 Manual No. M13-167-B0614Appendix O - Warranty Repair and ServiceBrookeldViscometersareguaranteedf

Strany 95 - VISCOSITY TEST REPORT

BROOKFIELD ENGINEERING LABORATORIES, INC. • 11 Commerce Blvd. • Middleboro, MA 02346 • TEL: 508-946-6200 or 800-628-8139 FAX: 508-946-6262 • www.brook

Komentáře k této Příručce

Žádné komentáře