Brookeld Engineering Labs., Inc. Page 3 Manual No. M/05-370-B0507
I. INTRODUCTION
TheBrookeldLFRATextureAnalyzermeasurestheresistanceofamaterialtoanappliedforce.
The force is applied through a vertical compression of the sample and the resistance is measured
through a load cell. This resistance can be interpreted to provide a measure of the texture or other
physical characteristics of the material.
TheLFRATextureAnalyzeristhemostrecentdevelopmentoftheoriginalBoucherJellyTester.
This original product was created as the Stevens Texturemeter evolving into the CNS Farnell LFRA
TA(LeatherheadFood ResearchAssociationTextureAnalyzer). Brookeld’senhanced design
maintains the characteristics of the original equipment while expanding the measurement capabili-
ties and ease of use by incorporating modern digital technology.
TheprincipleofoperationoftheLFRATextureAnalyzeristodriveaprobeintoamaterial.The
resistance of the material to this compression is measured by a calibrated load cell and reported
in units of grams on the instrument display. The measured load will be a function of the probe
geometry, speed of compression, test method, and sample preparation.
TherearefourloadcellrangesavailablefortheLFRATextureAnalyzerofferedbyBrookeld:
Model Load Cell Range (grams)
LFRA-100 100g
LFRA-1000 1000g
LFRA-1500 1500g
LFRA-4500 4500g
Higher load cell ranges are used for testing materials with a stronger structure.
I.1 Components
Please check to be sure that you have received all components, and that there is no damage. If
youaremissinganyparts,pleasenotifyBrookeldEngineeringoryourlocalBrookeldagent
immediately. Any shipping damage must be reported to the carrier.
Part Number Quantity
Component Part Number Quantity
LFRATextureAnalyzer varies 1
Probe varies per order
Operating Manual M05-370 1
Power Cord 1
115 Volt or DVP-65 1
230 Volt DVP-66
Optional
Bloom Strip TA-CS-100 or 1
TA-CS-1000
Calibration Weight Set (1) TA-CW-100C, -1000C, -1500C, -4500C 1
Standard Probe kit TA-P-KIT2 1
TexturePro Lite Software TA-T-PRO 1
Note:1.Optionalcomponentsmayincludeprobesorxtures.SeeAppendixAfordetails.
2. See III.9 for Calibration Checking (pg. 14).