Brookfield Dial Viscometer Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Měřící nástroje Brookfield Dial Viscometer. Brookfield Dial Viscometer User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 35
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Brookfield Engineering Laboratories, Inc. Page 1 Manual No. M/85-150-P700
BROOKFIELD DIAL VISCOMETER
Operating Instructions
Manual No. M/85-150-P700
Model No. _____________________
Serial No. _____________________
SPECIALISTS IN THE
MEASUREMENT AND
CONTROL OF VISCOSITY
T
EL
508-946-6200 or 800-628-8139 F
AX
508-946-6262
www.brookfieldengineering.com
BROOKFIELD ENGINEERING LABORATORIES, INC.
11 Commerce Boulevard, Middleboro, MA 02346-1031 USA
Please record the Model and Serial Number of your viscometer.
Having this information readily available will help us to assist you
should there be any questions regarding your instrument.
Zobrazit stránku 0
1 2 3 4 5 6 ... 34 35

Shrnutí obsahu

Strany 1 - 508-946-6262

Brookfield Engineering Laboratories, Inc. Page 1 Manual No. M/85-150-P700BROOKFIELD DIAL VISCOMETEROperating InstructionsManual No. M/85-150-P700M

Strany 2 - TABLE OF CONTENTS

Brookfield Engineering Laboratories, Inc. Page 10 Manual No. M/85-150-P700Remove the sample cup and attach the cone to the Viscometer (Note: left

Strany 3 - I. INTRODUCTION

Brookfield Engineering Laboratories, Inc. Page 11 Manual No. M/85-150-P700Turn the adjustment ring to the right (counterclockwise as you look down

Strany 4

Brookfield Engineering Laboratories, Inc. Page 12 Manual No. M/85-150-P700When you are satisfied the pins are just hitting (by observing acceptabl

Strany 5 - II. GETTING STARTED

Brookfield Engineering Laboratories, Inc. Page 13 Manual No. M/85-150-P700Each of the five available cones has a specific sample volume, as shown

Strany 6 - LV Series Viscometer

Brookfield Engineering Laboratories, Inc. Page 14 Manual No. M/85-150-P7004) Attach sample cup to viscometer and allow approximately 15 minutes fo

Strany 7 - 1234 567

Brookfield Engineering Laboratories, Inc. Page 15 Manual No. M/85-150-P700The ratio of (ωr) and (c) is a constant for any value of (r). Since (c)

Strany 8

Brookfield Engineering Laboratories, Inc. Page 16 Manual No. M/85-150-P700Wells-Brookfield Cone/Plate Viscometer Full Scale Ranges3.0° CONE SPINDL

Strany 9 - Figure A1

Brookfield Engineering Laboratories, Inc. Page 17 Manual No. M/85-150-P700Viscometer Ranges in Centipoise (1 cP = 1 mPa•s)Viscosity = Dial Reading

Strany 10 - Figure A3

Brookfield Engineering Laboratories, Inc. Page 18 Manual No. M/85-150-P700APPENDIX B - Viscosity RangesLV Series Viscometers with Spindles #1 - #4

Strany 11 - Figure A4

Brookfield Engineering Laboratories, Inc. Page 19 Manual No. M/85-150-P700UL AdapterCone/Plate ViscometerHelipath with T-Bar Spindles YULA-15 or 1

Strany 12 - Figure A7

Brookfield Engineering Laboratories, Inc. Page 2 Manual No. M/85-150-P700TABLE OF CONTENTS I. INTRODUCTION ...

Strany 13 - Table A1

Brookfield Engineering Laboratories, Inc. Page 20 Manual No. M/85-150-P700APPENDIX C - Variables in Viscosity MeasurementsAs with any instrument m

Strany 14 - Figure A9

Brookfield Engineering Laboratories, Inc. Page 21 Manual No. M/85-150-P700A repeatable viscosity test should control or specify the following:1) T

Strany 15

Brookfield Engineering Laboratories, Inc. Page 22 Manual No. M/85-150-P700APPENDIX D - Calibration ProceduresThe accuracy of the Dial Viscometer i

Strany 16 - RVTCP VISCOMETER

Brookfield Engineering Laboratories, Inc. Page 23 Manual No. M/85-150-P700Brookfield Engineering Laboratories does not recertify Viscosity Standar

Strany 17 - HBTCP VISCOMETER

Brookfield Engineering Laboratories, Inc. Page 24 Manual No. M/85-150-P700Calibration Procedure for a Thermosel SystemWhen a Thermosel System is u

Strany 18 - APPENDIX B - Viscosity Ranges

Brookfield Engineering Laboratories, Inc. Page 25 Manual No. M/85-150-P7005) After 1 hour, check the temperature of the viscosity standard fluid w

Strany 19 - Helipath with T-Bar Spindles

Brookfield Engineering Laboratories, Inc. Page 26 Manual No. M/85-150-P700D2. Consult with Brookfield or an authorized dealer to determine which

Strany 20

Brookfield Engineering Laboratories, Inc. Page 27 Manual No. M/85-150-P700Contact the Brookfield technical sales department or your local Brookfie

Strany 21

Brookfield Engineering Laboratories, Inc. Page 28 Manual No. M/85-150-P700RV Guardleg LV GuardlegFigure D1

Strany 22 - Refer to Brookfield catalog

Brookfield Engineering Laboratories, Inc. Page 29 Manual No. M/85-150-P700Figure E1 APPENDIX E - Models A & A-E Laboratory StandsUnpackingChec

Strany 23

Brookfield Engineering Laboratories, Inc. Page 3 Manual No. M/85-150-P700 I. INTRODUCTIONThe Brookfield Dial Viscometer measures fluid viscosity

Strany 24

Brookfield Engineering Laboratories, Inc. Page 30 Manual No. M/85-150-P700Remove the three (3) leveling screws from the base and discard the packi

Strany 25

Brookfield Engineering Laboratories, Inc. Page 31 Manual No. M/85-150-P700 APPENDIX F - Fault Diagnosis and TroubleshootingListed are some of the

Strany 26 - OIL VISCOSITY STANDARD FLUIDS

Brookfield Engineering Laboratories, Inc. Page 32 Manual No. M/85-150-P700Inaccurate Readings❏ Verify spindle, speed and model selection❏ Verify t

Strany 27

Brookfield Engineering Laboratories, Inc. Page 33 Manual No. M/85-150-P700 APPENDIX G - Warranty Repair and ServiceWarrantyBrookfield Viscometers

Strany 28 - Figure D1

Brookfield Engineering Laboratories, Inc. Page 34 Manual No. M/85-150-P700For repair or service in the United States return to:Brookfield Engin

Strany 29

Brookfield Engineering Laboratories, Inc. Page 35 Manual No. M/85-150-P700VISCOSITY TEST REPORTSAMPLE MODEL SPINDLE RPMDIAL READINGFACTORVISCOSITY

Strany 30

Brookfield Engineering Laboratories, Inc. Page 4 Manual No. M/85-150-P700 I.2 UtilitiesInput Voltage: 115 VAC or 230 VACInput Frequency: 50 or 60

Strany 31

Brookfield Engineering Laboratories, Inc. Page 5 Manual No. M/85-150-P700 II. GETTING STARTED II.1 OperationThe Brookfield Viscometer is powered b

Strany 32

Brookfield Engineering Laboratories, Inc. Page 6 Manual No. M/85-150-P700fluid surface, and bring the spindle to an upright position and thread on

Strany 33 - Foam Insert

Brookfield Engineering Laboratories, Inc. Page 7 Manual No. M/85-150-P700 .5 200 .5 800 .5 2K.5 4K.5 8K.5 20K.5 80K1 100 1 400 1 1K12K14K110K140K2

Strany 34

Brookfield Engineering Laboratories, Inc. Page 8 Manual No. M/85-150-P700II.3Considerations for Making MeasurementsIn taking viscosity measurement

Strany 35 - VISCOSITY TEST REPORT

Brookfield Engineering Laboratories, Inc. Page 9 Manual No. M/85-150-P700 APPENDIX A - Cone/Plate Viscometer Set-UpThe Wells-Brookfield Dial Visco

Komentáře k této Příručce